I started working with Advantage Database Server in 1999. If an application attempts to get more than 50 connections, a 6303 error will result. The MAX_TIMEOUTS setting must exist within a section titled "[SETTINGS]". Each server that the Advantage client wishes to connect to can have a section specifying the IP address and port. Source

You can ping the IP address from the client machine to the server machine. axServerConnect", it usually related to the IP address or port number specified in the connection or any firewalls that blocks the UDP traffic for the specified port. axServerConnect", it usually related to the IP address or port number specified in the connection or any firewalls that blocks the UDP traffic for the specified port. Problem Description: Attempting to connect to the Advantage Database Server returns the error 6420 or 6097 when the IP and PORT is used.

To change the maximum value, modify or add the MAX_CONNECTIONS parameter under the SETTINGS section in the ads.ini file. If you are using a third party firewall, check with their documentation on how to add an exception. 2 If the server name or IP address of the server has recently Forums Archive > Advantage DB > OLEDB > "Error 6097: Bad IP address specified in the connection path or in the ADS.INI file." Error 6097: Bad IP address specified in the The Advantage Database Server is currently running.

If you are using the standard Windows firewall go to the server and select Start > Settings > Control Panel > Windows Firewall and add UDP port 6262. Can I brine meat after cooking it? Reward Savings; Regular Savings; Advantage Money Market; Indexed …… Buy Canon EF-S 18-135mm f/3.5-5.6 IS STM Lens features EF-S Mount Lens, 29-216mm (35mm Equivalent). The ways to specify the Advantage server type in an application include: Using the AdsSetServerType function with the Advantage Client Engine API or the Advantage CA-Visual Objects RDDs.

Not sure if anyone is still reading this thread but I have a really strange advantage problem. Tuesday, August 28, 2012 10:10 AM Reply | Quote 0 Sign in to vote Hi John, For the intermittent error message "Error 6097: Bad IP address or port specified in the This allows future connection attempts to avoid some of the timeout periods associated with the Advantage Database Server discovery process. https://devzone.advantagedatabase.com/dz/webhelp/Advantage9.0/server1/ads_ini_file_support.htm If located in the users home directory the ads.ini file should be named .ads.ini (note the initial "dot").

The record cache is primarily intended to speed up performance of applications that are oriented mainly toward user interaction. For example, data bound grids can be highly network intensive because of the number of record requests they make. Repairing the IP Protocol Stack may be a solution if you want to further troubleshoot the issue. The client-specified connection parameters override this setting if they are given.

All new questions should be directed to the appropriate forum at the SAP Community Network (SCN). ← Previous Post Next Post → If you enjoyed this article please consider sharing it! The valid values for this setting are "Internet", "Always", and "Never". On the test box the database is refreshed nightly. Once the restore has finished the windows service continues running correcly for a few attempt but then this error occurs.

Switching to IPv4 may correct your issue, but you will need your network tech to configure that. this contact form Make sure the IP address of the server and the sever name are correct. 3 While much less common, there are third party firewalls and the Windows Live Onecare firewall that The setting specified here will be used only if the connect request from the client did not specify a communication type. Recent To make sure the Advantage Database Serverstarted Links WordPress.com WordPress.org Archives March 2009(1) Categories Error Experiences RSS Entries RSS Comments RSS Site info My Advantage Database Server' Personal Note Create

These steps are generally executed very quickly and the server is found and a connection is made. HomeSitemap Services Welcome Home » Software » Advantage Error 6097 Advantage Error 6097 Posted on admin in Software on February 28, 2015 Comments Off on Advantage Error 6097 Gulf Pines Vacation The INTERNET_IP and INTERNET_PORT settings must exist within a section titled "[]", where is the name of the server upon which the Advantage Database Server is running. have a peek here For IPX packets, the default packet size is 576 bytes.

The remote computer is connected to the internet via a business broadband circuit. An error has occurred during report processing. Adjusting this size is not recommended unless you are sure it will help performance.

LAN_IP/LAN_PORT The IP address and port of the server on which the Advantage Database Server is running can be specified in the ads.ini file.

TS07A - Laser Scanners I, 6097 Gokcen Karsidag and Reha Metin Alkan Analysis of The Accuracy of Terrestrial Laser Scanning Measurements (6097)… 18.03.2013 · Books shelved as world-war-1: All Quiet on the For example, to force all future table opens to strip the carriage return line feed pairs from memos, you need to create an ads.ini file that contains the entry: [SETTINGS] ADS_FORCE_CLIPPER_MEMOS Good read, I also am getting intermittent Error 6420 at a clients site.Regards November 7, 2015 at 12:16 AM Stephen Arentz said... See the topic, Database Aliases and the ads.ini File in the Advantage TDataSet Descendant Help documentation (ADE.HLP or ade.htm) for more information. (Note that each of the Advantage products and their

More information can be found in this knowledgebase item: Repairing the IP Protocol Stack on Windows XP/2003 Was This Item Helpful? February 14, 2014 at 12:36 PM jmaybe said... I've tried turning off the connection pooling in the connection string AdsConnection.FlushConnectionPool(_connectionString) AdsConnection.FlushConnectionPool() Please note that I don't use the ADS.ini file, the IP address and port number are in the Check This Out The default protocol packet size is determined by which protocol is being used by the Advantage communication layer.

In these situations it is possible to use the [DRIVES] section to define virtual drive letters. The drawback is the initial time to read the rowset. MAX_CONNECTIONS This setting changes the default maximum number of Advantage Database Server connections. In general, the default value of 30 will result in a timeout period of approximately 15 seconds. [SETTINGS] // A Default value of 30 is used if this is 0 or

If you get a standard IP number pinging (for example 192.168.1.1). My hunch is this broadband service is dropping out and effectively killing the remote connection between SSRS and Sybase Advantage Server at the remote end but SSRS sees it as still Located in the prestigious Gulf Pines Community, this 3 bedroom, 2 Bath …… ABB AFS660 Switch High-availability Ethernet device … – Communication networks | 3 ABB AFS660 switches The Advantages at Last posting was on 2008-06-30 23:38:28.0Z tim sines Posted on 2008-05-19 21:50:54.0Z From: "tim sines" Newsgroups: Advantage.OLEDBSubject: Error 6097: Bad IP address specified in the connection path or in the ADS.INI

We of course have SQL reports running under SSRS which aren't affected by the same problem, these run locally on the server. Any help would be much appreciated. Reward Checking; Coast Free Checking; Senior Checking; Saving. Would this be considered as plagiarism?

If the Advantage server types in which to connect are specified as either the Advantage Database Server or the Advantage Local Server, the Advantage application will first attempt to connect to The MAX_CONNECTIONS setting must exist within a section titled "[SETTINGS]". Could the Industrial Revolution be delayed indefinitely?