Home > Advantage Database > Advantage Database Server Error 6610

Advantage Database Server Error 6610

Once these files are removed, reinstall the current version and upon entering the practice reenter all the registration information as it was previously entered. ********* If you need help with Medisoft Use User DSNs only when accessing data over the Advantage Internet Server. 9. 6610 errors can occur after the Watch Dog process removes the connection. axServerConnect Path: (correct path is here) Alias: agencyDB Type: Remote"Solution:In case the clients were never able to connect to the server, it is possible that the installation of the Advantage Server This new claim form can begin to be used Jan 6, 2014 and is REQUIRED by April 2014. Source

A 6610 error can occurs immediately after connection to the 2.6 version of the Advantage Internet Server ( AIS ) if the Watch Dog Cleanup Interval setting was changed and AIS.EXE When your computer wakes from sleep mode you will have an error in Medisoft because of this. Our New Insurance Claim Forms Are Compatible With the NEW CMS 1500 2014 Claim Form Our free quick start "How to use Medisoft" video training will help you understand how to axServerConnect. " After restarting apache everything is working as before.

Sometimes it works ok for 4-5 days and sometimes I have to restart apache 5 times in 2 min. For systems using the Windows Firewall on Windows XP or 2003 Server. 1. on novell netware is serving about 100 *.dbf tables for clipper program all the time and they don't get 6610 error only apache, ads8.1 is always on line as win2003 with Another way to troubleshoot the 6610 error is to reduce the packet size.

Some of these applications my cause Medisoft to perform more slowly than it normal. It does this a number of times (30 by default or whatever MAX_TIMEOUTS is set at). When this happens, Medisoft loses the connection it currently has over the network to the database on the server. The CPU utilization on the server is 100 percent.

From the Add a Program window, click on Browse. 4. Ref No:020729-1481Last Modified:Wednesday, August 14, 2002Product:Advantage Client Engine 32-bitCategory:Error CodesTitle:6610 errors with 32-Bit ClientsProblem Description:Following are several problems and solutions related to 6610 errors and 32-Bit Advantage clients.Solution:1. How to solve this problem? Please try the following: - Disable the antivirus and firewalls on the machine, - Uninstall ADS - Reboot server - reinstall ADS - try to connect while the antivirus and firewall

A client application tries to connect to the Advantage Database Server. The medisoft error 7074 indicates that either a table is missing from the dataset, or that there is a table in the dataset that was not originally part of the Data Me: Horatio!! Try stopping or un-installing the application that owns the WSOCK32.DLL.

Solution: This requires correction by a Network Technician. Me: Horatio, I have change php.ini and upgrade from php 5.2.3 to 5.2.9-2 and same 6610 error is showing. This is because the Advantage Server service does not have rights to the share. In regards to general networking, always check cabling to ensure cables are plugged into the computers and routers fully.

IV. this contact form The claims program is easy to use especially in the windows environment. Make sure that any other users have closed out of the Medisoft Program (this includes any add on products such as Office Hours Pro or Final Draft). Yes No © Copyright 2016, Sybase Inc.

My users are very angry and my boss is threatening with dismissal. Restart AIS.EXE after making changes to the Watch Dog Cleanup interval setting. 7. Click on the "Version" tab and verify the "Company Name" is Microsoft. have a peek here Posted in: Medisoft, Networking Your Shopping CartYour cart is empty                      Call now for your free consultation!

Phone: (951) 208-7226 Copyright

Some other potential solutions: Further Advantage Troubleshooting At-Your-Service Software, Inc, 450 Bronxville Rd, Bronxville, NY 10708 Phone: 914-337-9030 or 1-888-FC-LOWER (325-6937) email: [email protected] Toll Free: 1-888-691-8058 | Double-click on the Server folder. 8. Then, when the workstation is connected to another network and logs into a new domain, other workstations may use it as the browse master, and thereby use it's old domain information,

From the server, click on Start, Programs, Advantage Database Server, and ADS Configuration Utility. 2.

Older causes and solutions to 6610 errors can be found at http://devzone.advantagedatabase.com/dz/content.aspx?Key=17&RefNo=020729-1481 Was This Item Helpful? There are two possible solutions to this issue. If you want your application to check for the Advantage Database Server each time it attempts an "ADS_REMOTE" connection, you need to create an ads.ini file with the following entry: [SETTINGS] Change the client to connect using TCP/IP versus UDP.

If you continue to experience this issue, contact support at 888-691-8058 (charges apply). ******** Medisoft Error 7004: Maximum Number of Work Areas Exceeded Solution to Medisoft Error 7004- This error is This error occurs if you copy data files from one practice to another, without using the MediUtils. ****** Medisoft Error: This Option Requires Other Users to Exit the Program (while converting) Click on Apply and Exit. ****** Medisoft Error 7074: The Table ID Stored in the ADT Table Does Not Match the ID Stored in the Advantage Data Dictionary file Solution to http://focalhosting.com/advantage-database/advantage-database-server-error-7008.html Home Services Info Submit Support Ticket Start Remote Session Contact Us Shopping Cart Buy Now CostGuard Food Costing Software Lowering Your Food Costs Every Day Search for: wordpress linkedin twitter Whatis

You may have to configure firewalls at both the client and server. Click here to access article 129890: How do I Restore a Medisoft Backup?, or click on the articles link located on the right side of this screen. 3. Ensure the following programs are trusted for network access:Workstation:MAPA.exe (or Medisoft)OHP.exe (or Office Hours)Server:ads.exeadsver.exeads_cfg.exe Sign in|Recent Site Activity|Report Abuse|Print Page|Powered By Google Sites Real-time backup solutions in most cases will place a lock on the file(s) they are backing up.

When dealing with a client / server application like Medisoft locking these files can cause data in use errors in the form of 7xxx errors and 6xxx errors. Out-dated or 16-bit NIC cards may have problems. Are you having problems with Medisoft? This will cause the WSOCK32.DLL to be a Microsoft's file and the application that owns the proprietary DLL will use its own DLL. "WinProxy" is one example of an application that

It is generated if the MAX_TIMEOUTS value is hit while waiting for a response. This setting is documented in the Advantage help file. 3. Click OK and shutdown/restart the computer. Also, ensure that any scanning is done locally and not over the network.

Note: At least one computer in each workgroup must have the ability to become the master browse server. Stop and Restart the Advantage Database Server. Go to Network Neighborhood, Properties, Configuration Tab, double-click the File and Printer Sharing component. 2. Me: Version is 8.10.0.17!?

Medisoft Error: This Option Requires Other Users to Exit the Program (while converting) If you get this error message while in the conversion process, please contact our tech support department at When I have less than 30 requerst (server-info) speed is ok but it exponentially slows above 40 request and on more than 50 request it stops. The 9029 and 7013 errors will be reported in the Advantage Database Server error log, ads_err.dbf, along with a corresponding Windows NT/2000/2003 error 5 (access denied error). However, it will not solve other underlying network issues that may be causing the error.

In addition, you should exclude the Medisoft program folder and data folders from being scanned by these programs. As a last resort, backup, then uninstall all previous versions of Medisoft from the machine and delete the C:\Program Files\Medisoft directory.

© Copyright 2017 focalhosting.com. All rights reserved.